TM 5-2420-222-20-1
ORGANIZATIONAL TROUBLESHOOTING CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
b. If multimeter reads less than 11 vdc, turn ignition lock switch (6) counterclockwise to off. Repair wire from
starter neutral safety switch to ignition lock switch (page 2-137).
Step 20.
Using multimeter set to 30 vdc scale, place red probe on starter neutral safety switch terminal (9)
and black probe on transmission case (8). Check for 11 to 13 vdc on multimeter.
a. If multimeter reads 11 to 13 vdc, go to step 21.
b. If multimeter reads less than 11 vdc, turn ignition lock switch (6) counterclockwise to off. Replace
starter neutral safety switch (page 2-471).
TA242719
2-27
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |