TM 5-2420-222-20-1
ORGANIZATIONAL TROUBLESHOOTING CONTINUED
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
a. If terminals (6 and 7) and wire terminals (8 thru 10) are not loose, corroded, frayed or broken, go
to step 9.
b. If connection on terminal (6) is loose, tighten nut (11) using 3/8 inch box wrench.
c. If connection on terminal (7) is loose, tighten nut (12) using 318 inch combination box and open-
end wrench.
d. If connection on terminal (6 and 7) and wire terminals (8 thru 10) are corroded, clean using wire
brush.
e. If terminals (6 or 7) are broken, replace 40 ampere circuit breaker (page 2-516).
f. If connection on wire terminals (8 thru 10) are frayed or broken, repair (page 2-137).
2-21
|