TM 5-2410-237-23
BLADE TILT AND RIPPER PILOT VALVE ASSEMBLY REPAIR - CONTINUED
0245 22
ASSEMBLY - CONTINUED
9.
Install three new O-rings (12) at large valve ports, new O-rings (13) at smaller ports and two new small O-rings (14) at
smallest ports in inlet manifold (11).
10.
Repeat step 9 to install new O-rings (12, 13 and 14) on ripper pilot valve (9) and blade tilt pilot valve (10).
CAUTION
Ensure all O-rings and seals are properly seated when assembling manifolds and pilot valves. Cut or
pinched O-rings or seals could cause leaks and system malfunctions.
11.
Position and carefully align inlet manifold (11), blade tilt pilot valve (10), ripper pilot valve (9) and outlet manifold (8)
together.
12.
Install three bolts (7) to secure manifolds (8 and 11) and pilot valves (9 and 10).
8
12
14 12
7
14
9
14
10
12
11