TM 5-2410-237-23
TRANSMISSION PRESSURE CONTROL VALVE REPAIR - CONTINUED
0245 17
CLEANING AND INSPECTION
WARNING
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low toxic
material. However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in
well-ventilated areas. Keep away from open flames and other sources of ignition. Failure to follow this
warning may cause injury or death.
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure
when drying parts with compressed air. DO NOT direct compressed air against human skin. Failure to
follow this warning may result in injury. Make sure air stream is directed away from user and other
personnel in the area. To prevent injury, user must wear protective goggles or face shield.
1.
Clean all parts in solvent cleaning compound. Ensure all passages in valve body are clean.
2.
Thoroughly dry all parts and all passages in valve body with compressed air.
3.
Inspect parts for nicks, burrs, cracks, breaks, distortion or other damage IAW WP 0241 00.
4.
Check valves for free movement in valve body bores.
5.
Replace damaged or defective parts.
0245 17-4