TM 5-2410-237-23
TORQUE DIVIDER REPAIR - CONTINUED
0245 14
DISASSEMBLY - CONTINUED
WARNING
Use extreme caution when handling heavy parts. Provide adequate support and use assistance during pro-
cedure. Ensure that any lifting device used is in good condition and of suitable load capacity. Keep clear of
heavy parts supported only by lifting device. Failure to follow this warning may result in injury or death.
NOTE
Housing weighs 89 lb (40 kg).
8.
Remove eight capscrews (10) and lockwashers (11) from torque divider housing (2). Discard lockwashers.
9.
Install two lifting links on torque divider housing (2) with capscrews (10) and attach lifting device.
10.
Lift housing (2) from torque divider (12).
11.
Remove preformed packing (13) from torque divider (12). Discard preformed packing.
12.
Remove two capscrews (14) and washers (15) 180 degrees apart from each other. Tip assembly and drain oil into a drain
pan.
13.
Remove remaining 32 capscrews (14) and washers (15) from torque divider (12).
10
11
LIFTING LINK
2
13
14,15
12
11
421-0159
0245 14-3
Change 1
|