TM 5-2410-237-23
GOVERNOR AND FUEL INJECTION PUMP HOUSING SEPARATION/ASSEMBLY - CONTINUED
0245 10
CLEANING AND INSPECTION
WARNING
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low toxic
material. However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in
well-ventilated areas. Keep away from open flames and other sources of ignition. Failure to follow this
warning may cause injury or death.
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure
when drying parts with compressed air. DO NOT direct compressed air against human skin. Failure to
follow this warning may result in injury. Make sure air stream is directed away from user and other
personnel in the area. To prevent injury, user must wear protective goggles or face shield.
1.
Remove all gasket material from surfaces.
2.
Clean all components and surfaces with solvent cleaning compound.
3.
Dry all components with compressed air.
4.
Inspect for damage, pitting or corrosion IAW WP 0241 00.
5.
Repair or replace damaged components.
ASSEMBLY
1.
Install new seat (12), new wave washer (11), new washer (10), new wave washer (9), and new spring (8) in governor
housing (6).
2.
Place new gasket (13) on governor housing (6), and
install governor housing on fuel injection pump hous-
ing (7). Install eight bolts (5).
3.
Install new gasket (4), cover (3), new spring (2), and
six bolts (1).
2
3
1
4
421-0177
4.
Install governor and fuel injection pump housing assembly (WP 0055 00).
5.
Install fuel transfer pump (WP 0042 00).
END OF WORK PACKAGE
0245 10-3
Change 1
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |