FUEL INJECTION PUMP MAINTENANCE - CONTINUED
0245 09
CLEANING AND INSPECTION
WARNING
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low toxic
material. However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in
well-ventilated areas. Keep away from open flames and other sources of ignition. Failure to follow this
warning may cause injury or death.
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure
when drying parts with compressed air. DO NOT direct compressed air against human skin. Failure to
follow this warning may result in injury. Make sure air stream is directed away from user and other
personnel in the area. To prevent injury, user must wear protective goggles or face shield.
1.
Clean all components in solvent cleaning compound.
2.
Thoroughly dry all components with compressed air.
3.
Inspect components for cracks, breaks, distortion or other damage IAW WP 0241 00.
4.
Replace any damaged components.
ASSEMBLY
CAUTION
Keep all components clean. Contaminants may cause rapid wear and shortened component life.
1.
Apply clean lubricating oil to all components before assembly.
2.
Install spring (18) and check valve assembly (17) in cap (16).
3.
Install cap (16) on barrel (13) and install ring (15).
NOTE
Do not slide cap across barrel. Check valve assembly in cap may damage face of barrel.
Change 1
0245 09-4