TM 5-2410-237-23
AIR CONDITIONING INSTALLATION INSTRUCTIONS - CONTINUED
0229 03
A/C UNIT INSTALLATION - CONTINUED
WARNING
Turn battery disconnect switch off before working on any electrical system component. Failure to follow
this warning could result in personal injury or damage to equipment.
1.
Make sure all armor is installed and all bolts are tight-
1
ened before beginning (WP 0228 00).
2.
Prior to installation of A/C unit, cut out roof section in
FOPS roof (1) and drill six holes (2) using 4R9909
plate assembly (3) as a template.
3.
Loosen bolts holding plate assembly (3) and raise
plate assembly a minimum of 0.197 in. (5 mm) above
FOPS roof.
421-0322
2
3
4.
Place RTV silicone compound in between plate
3
SEALANT
assembly (3) and FOPS roof (1) around cutout.
0.197 IN. (5 MM)
1
421-0323
5.
Retighten all bolts IAW Table 1.
7
6.
Install two filter retainer brackets (4) on rear of A/C
4
unit (7) with four 5/16-18 x 0.75 in. bolts (5) and
washers (6).
5,6
421-0324
Change 1
0229 03-2
|