|
|
TM 5-2410-237-23
RIPPER HYDRAULIC LINES AND FITTINGS REPLACEMENT - CONTINUED
0212 00
INSTALLATION
CAUTION
Wipe all line ends, line fittings and mounting surfaces clean and dry before installation, to prevent con-
tamination of hydraulic system.
Utilize line wrenches for installation to avoid damage to fittings and connectors.
NOTE
Lightly coat new O-rings with clean oil before installation.
1.
For hydraulic lines with connector fittings, install fitting (7). Install new O-ring (8) to fitting (7) and connect line (6) to
fitting.
2.
For hydraulic lines with split or regular flange fittings, install new O-ring (5) to end of line (4). Install line with two split
flanges or regular flange (3), four washers (2) and capscrews (1).
NOTE
Mounting hardware for clamps may vary depending on type and location of clamp.
3.
For lines held in position with clamps, install clamp (11) on line or lines with washer (10) and capscrew (9).
4.
Check level in hydraulic tank. Refill tank as needed and bleed air from system (WP 0225 00).
5.
Cycle cylinders and check for proper operation and leaks. Stop engine and reposition fittings if hydraulic lines pull tight.
6.
Ensure that oil is still visible in sight gage on hydraulic tank. Add oil as needed. (WP 0225 00).
END OF WORK PACKAGE
0212 00-3
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |