TM 5-2410-237-23
BLADE TILT CYLINDER REPAIR - CONTINUED
0210 00
ASSEMBLY - CONTINUED
2.
Install new backup ring (14) and new O-ring (13) in inner groove of head (1).
3.
Install new seals (11 and 12) in head (1).
4.
Use sandpaper or emery cloth to scuff surfaces of counterbore in head (1) and outside diameter of new seal (10). Clean
counterbore in head and scruffed surface of seal thoroughly with quick-cure primer, until neither component discolors a
clean white towel. After cleaning, do NOT touch cleaned surfaces. Handle seal by lip only.
NOTE
Quick-cure primer will dry in approximately 30 seconds.
5.
Apply quick-cure primer to counterbore of head (1) and to metal shell of seal (10) and allow to dry.
NOTE
Do NOT allow bearing mount compound to contact sealing lip.
6.
Apply bearing mount compound evenly but not excessively to counterbore of head (1) and to metal shell of seal (10).
7.
Install seal (10) into counterbore of head (1), with sealing lip facing inward. Seat seal firmly against bottom of counter-
bore. Wipe away excess bearing mount compound. Allow compound 15 minutes to dry.
10
11
12
1
14
13
387-656
0210 00-5
|