BLADE TILT AND RIPPER PILOT VALVE ASSEMBLY REPLACEMENT - CONTINUED
0204 00
INSTALLATION
WARNING
Wipe all sealing surfaces on hoses and valve clean and dry before installation to prevent contamination of
hydraulic system.
NOTE
Lightly coat new O-rings with clean oil before installation.
If equipped with ripper, pilot valve assembly weighs 24 lb (11 kg). Otherwise, pilot valve assembly
weighs 17 lb (8 kg).
1.
Use two wrenches to install pilot valve assembly (7) on side of control housing (5) with three capscrews (18), washers
(19) and nuts (17).
2.
Install new O-ring (16) on hose (15) and connect hose to back side of pilot valve assembly (7).
3.
Install new O-rings (14) on three hoses (12) and connect hoses to ripper pilot valve (13) of pilot valve assembly (7).
4.
Install new O-rings (11) on two hoses (9) and connect hoses to blade tilt pilot valve (10) of pilot valve assembly (7).
5.
Install new O-rings (8) on two hoses (6) and connect hoses to front side of pilot valve assembly (7).
11
5
9
6
7
11
8
6
387-604
12
15
16
14
17,18,19
10
13
0204 00-4