TM 5-2410-237-23
HYDRAULIC PUMP REPAIR - CONTINUED
0200 00
ASSEMBLY - CONTINUED
NOTE
Seals (32 and 34) are two-piece seals. Ensure that preformed packing seal is in plastic seal before seals are
installed.
17.
Install two new seals (32) with preformed packing in contact with plate (29).
18.
Install two new seals (34) with preformed packing in contact with plate (33).
19.
Position plates (33 and 29) on plate (31) and install four capscrews (30) in holes nearest arrows that are in the same
direction as arrow on plate (29). These arrows show direction of pump rotation and must be assembled with arrows in
the same direction.
20.
Install new seal (28) and new O-ring (27) on sub-assembly (25), with seal installed toward pressure source.
21.
Install new O-ring (26) in end cover (1).
22.
Install sub-assembly (25) on end cover (1), with sub-assembly positioned so pins in plate (29) are in alignment with
mounting holes in center cover (2).
23.
Install new packing (24) on end cover (1).
24.
Install four bolts (23) and tighten bolts to 45 lb-ft (61 Nm).
25
30
32
34 33
24 27
26
1
23
32
29
31
34
28
2
387-498
0200 00-8
|