HYDRAULIC PUMP REPLACEMENT - CONTINUED
0199 00
INSTALLATION - CONTINUED
NOTE
On tractors with ripper attachment, a second hose is connected to hydraulic pump manifold in place of
cover (1). If equipped, repeat step 6 to install ripper hose.
6.
Install new O-ring (6) and hose (5) on manifold (7) with split flange (4), four capscrews (2) and flatwashers (3).
6 (HIDDEN)
1
14
7 2,3
4
13
4
5
12
10
8,9
11
387-500
7.
Refill hydraulic tank and bleed air from system (WP 0225 00).
8.
Check hydraulic pump for leaks and proper operation (TM 5-2410-237-10).
9.
Install floor plates (WP 0171 00).
END OF WORK PACKAGE