TM 5-2410-237-23
TRANSMISSION OIL SAMPLING VALVE REPLACEMENT
THIS WORK PACKAGE COVERS
Removal, Installation
INITIAL SETUP
Tools and Special Tools
Materials/Parts - Continued
O-ring (2)
Tool kit, general mechanic's (Item 122, WP 0250
Equipment Condition
Materials/Parts
Engine OFF and cool (TM 5-2410-237-10)
Transmission cool (TM 5-2410-237-10)
Oil, lubricating (Item 23, 24 or 25 WP 0250 00)
REMOVAL
1.
Remove oil sampling valve (1) from top of transmission oil pump on right side of engine compartment.
2.
Discard O-ring (2).
1
2
387-277
INSTALLATION
NOTE
Lightly coat new O-ring with clean oil before installation.
1.
Install new O-ring (2) on oil sampling valve (1).
2.
Install oil sampling valve (1) onto transmission oil pump on right side of engine compartment.
3.
Check oil sampling valve for proper operation and leaks.
END OF WORK PACKAGE
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |