TM 5-2410-237-23
RADIATOR FILLER CAP AND RELIEF VALVE REPLACEMENT - CONTINUED
0067 00
RELIEF VALVE REMOVAL
1.
Remove five capscrews (3) and washers (4).
3
2.
Remove access cover (5).
4
3.
Remove flow control thermostat (6).
5
4.
Remove two gaskets (7) with plate (8). Discard gas-
6
kets.
7
RELIEF VALVE INSTALLATION
8
1.
Install two new gaskets (7) with plate (8).
7
2.
Install flow control thermostat (6).
3.
Install access cover (5).
4.
Install five washers (4) and capscrews (3).
5.
Pressure test radiator as needed to verify cooling sys-
tem has no leaks and to verify operation of relief valve
387-265
6.
Start engine and check for coolant leaks (TM 5-2410-
237-10).
END OF WORK PACKAGE