TM 5-2410-237-23
AIR CLEANER DUST EJECTOR ASSEMBLY REPLACEMENT
THIS WORK PACKAGE COVERS
Removal, Installation
INITIAL SETUP
Tools and Special Tools
Equipment Condition
Tool kit, general mechanic's (Item 122, WP 0250
Engine OFF and cool (TM 5-2410-237-10)
WARNING
If NBC exposure is suspected, personnel wearing protective equipment should handle all air cleaner
media. Consult your NBC Officer or NBC NCO for appropriate handling or disposal procedures.
NBC contaminated filters must be handled using adequate precautions (FM 21-40) and must be dis-
posed of by trained personnel.
REMOVAL
1.
Remove two capscrews (1) from dust ejector tube (2) at bottom of muffler (3).
2.
Loosen hose clamp (4) holding dust ejector hose (5)
3
5
4
on precleaner body (6).
2
3.
Remove dust ejector tube (2) from precleaner body (6)
6
and muffler (3).
4.
Loosen hose clamp (7) and separate dust ejector hose
(5) and tube (2).
1
INSTALLATION
1.
Assemble dust ejector tube (2) and hose (5) and
tighten hose clamp (7).
2.
Slide dust ejector hose (5) onto tube in filter body (6)
7
and tighten clamp (4).
3.
Install dust ejector tube (2) to bottom of muffler (3)
with two capscrews (1).
387-184
END OF WORK PACKAGE
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |