AIR CLEANER MAINTENANCE - CONTINUED
0046 00
INSTALLATION
1.
Install new gasket (8) over studs on air cleaner outlet
7
8
pipe (7).
387-133
2.
Position filter housing (6) with filter body (3) inserted up through opening in hood. Align eight holes in filter housing
with eight studs in air cleaner outlet pipe (7) and slide housing onto studs.
3.
Install two new lockwashers (5) and capscrews (4). Tighten capscrews.
4.
Slide dust ejector tube (2) onto filter body (3) and tighten hose clamp (1).
5.
Install air cleaner filter elements (WP 0045 00).
6.
Install hood (WP 0159 00).
7.
Run engine and check for proper operation (TM 5-2410-237-10).
3
1
3
6
2
7,8
387-130
4,5
387-131
END OF WORK PACKAGE