VIBRATION DAMPER REPLACEMENT - CONTINUED
0029 00
CLEANING
WARNING
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low toxic
material. However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in
well-ventilated areas. Keep away from open flames and other sources of ignition.
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle pressure
when drying parts with compressed air. Use a maximum of 30 psi (207 kPa) when cleaning compo-
nents. DO NOT direct compressed air against human skin. Failure to follow this warning may result in
serious injury or death. Make sure air stream is directed away from user and other personnel in the
area. To prevent injury, user must wear protective goggles or face shield.
Clean removed parts with solvent cleaning compound. Dry thoroughly with compressed air.
INSPECTION
1.
Inspect vibration damper and adapter for cracks or other damage. Replace if necessary.
2.
Check two dash marks on perimeter of vibration damper. If marks are not aligned, replace vibration damper.
INSTALLATION
1.
Position adapter (3) to hub of crankshaft pulley (4).
4
2
3
1
387-258
2.
Position vibration damper (2) on adapter (3) and install six capscrews (1). Tighten capscrews to 75 lb-ft (102 Nm).
3.
Install crankcase guard (WP 0157 00).
END OF WORK PACKAGE