TM 5-2410-237-23
UNIT MAINTENANCE PREVENTIVE MAINTENANCE CHECKS AND
SERVICES (PMCS) - CONTINUED
0010 00
Table 1. Unit Maintenance Preventive Maintenance Checks and
Services (PMCS) for the D7G Tractor - Continued.
LOCATION
ITEM TO
ITEM
MAN-
CHECK/
NO.
INTERVAL
HOURS
SERVICE
PROCEDURE
24.1
Semiannual
Air Condi-
tioner (If
Equipped)
WARNING
Liquid refrigerant, when exposed to air,
quickly evaporates and will freeze skin or eye
tissue. Use care to prevent refrigerant from
touching your skin or eyes. Use protective
gloves and goggles. Serious injury or blind-
ness may result if you come in contact with
liquid refrigerant.
Refrigerant R-134a air conditioning systems
should not be pressure tested or leak tested
with compressed air. Combustible mixtures of
air and R-134a may form, resulting in fire or
explosion, which could cause injury or death
to personnel.
DO NOT work in an area where refrigerant
may contact an open flame or burning mate-
rial such as a cigarette. When refrigerant con-
tacts extreme heat, refrigerant breaks down
into poisonous phosgene gas which, if
breathed, causes severe respiratory irritation.
DO NOT breathe fumes from an open flame
leak detector.
NOTE
Refrigerant is odorless. As a result, all of it
may leak away and not be noticed until system
stops cooling. All vehicle refrigerant systems
lose some refrigerant depending on the condi-
tion of system. Higher loss rates signal a need
to locate and repair leaks.
Leaks are most often found at the compressor
hose connections and at various fittings and
joints in system. If unapproved replacement
hoses are installed, refrigerant can be lost
through hose permeation.
0010 00-10
Change 1
|