TROUBLESHOOTING PROCEDURES - CONTINUED
0006 00
Table 6. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
13. Lamp(s) Will Not Light - Continued.
6.
Test exterior light switch.
a. Place battery disconnect
switch in OFF position.
b. Set
to
(Ω)
appropriate  ohm
range.
c. Disconnect dark green
wire from light switch.
d. Connect meter as shown
to measure continuity.
EXTERIOR
LIGHT SWITCH
387-894
e. Turn exterior light switch
1. If continuity is indicated,
to ON position.
repair open circuit in dark
green wire (WP 0242 00).
2. If no continuity is indicated,
replace exterior light switch
0006 00-58