TM 5-2410-237-23
TROUBLESHOOTING PROCEDURES - CONTINUED
0006 00
Table 6. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
6.
Solenoid and Starting Motor Operate;
b. Connect meter positive
Engine Cranks Slowly - Continued.
lead to negative terminal
on starting motor and
meter negative lead to
chassis ground.
c. Place battery disconnect
switch to ON position.
d. Crank engine and observe
If voltage exceeds 0.4 volts,
meter.
clean and tighten cable
connections at batteries, starting
motor and chassis ground points.
G
S
MTR
(+)
(-)
BAT
387-885
7.
Test positive cable voltage
from batteries to solenoid.
a. Place battery disconnect
switch in OFF position.
0006 00-47
Change 1
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |