TM 5-2410-237-23
TROUBLESHOOTING PROCEDURES - CONTINUED
0006 00
Table 6. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. If continuity is indicated,
5.
Starting Motor Inoperative - Continued.
c. Connect meter leads as
replace starter relay (WP
shown in the illustration
below
and
measure
continuity.
2. If continuity is not indicated,
repair circuit(s) in question
387-880
11. Test voltage to start switch.
a. Place battery disconnect
switch in OFF position.
b. Disconnect orange lead
from start switch BAT
terminal.
c. Set
to
appropriate voltage range.
d. Connect meter positive
lead to orange lead
(harness
side)
and
negative lead to chassis
ground.
0006 00-41
Change 1
|