BLADE LIFT CYLINDER REPAIR - CONTINUED
0158 00
DISASSEMBLY - CONTINUED
7.
Remove packing (10) from head (1). Discard packing.
8.
Remove preformed packing (11) and O-ring (12) from inner groove on head (1). Discard preformed packing and O-ring.
9.
Remove packing retainer (13), preformed packing (14) and ring spacer (15) from piston (9). Discard packing retainer,
preformed packing and ring spacer.
11
12
9
1
13
15
10
14
386-476
386-475
CLEANING AND INSPECTION
WARNING
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low toxic mate-
rial. However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in well-venti-
lated areas. Keep away from open flames and other sources of ignition.
1.
Clean all sealing surfaces and tube assembly connections with solvent cleaning compound and allow to dry.
2.
Inspect internal casing of cylinder and internal parts of cylinder for cracks, wear, scoring and damage. If components
and parts are not serviceable, replace lift cylinder.
3.
Ensure mating surfaces for bearing sleeves are clean and not damaged.
0158 00-3