TM 5-2410-233-23
HYDRAULIC TILT CONTROL VALVE REPLACEMENT - CONTINUED
0150 00
REMOVAL - CONTINUED
5.
Remove six capscrews (11), lockwashers (12), two bolts (13) and lockwashers (14) from manifold (3). Discard lock-
washers.
6.
Separate manifold (3) from mounting plate (8). Remove and discard four O-rings (15) from bores of manifold.
7.
If required for cleaning and inspection, remove plug (16) and O-ring (17) from manifold (3). Discard O-ring.
8
3
13,14
15
17
16
TILT
11,12
CONTROL
VALVE
15
3
8
386-744
386-746
0150 00-3
|