TM 5-2410-233-23
ROLLOVER PROTECTIVE STRUCTURE (ROPS) REPLACEMENT - CONTINUED
0131 00
REMOVAL
1.
Attach a suitable lifting device to lift points on roof of ROPS (1).
2.
Remove two capscrews (2), lockwashers (3), flatwashers (4) and grabhandle (5) from ROPS (1). Discard lockwashers.
3.
Repeat step 2 for other grabhandles (5).
4.
Remove nut (6), and capscrew (7), from each leg of ROPS (1).
5.
Lift ROPS (1) and remove from mounts (8). Remove four pads (9).
1
5
6
7
4
6,7
8
3
2
9
386-455
INSTALLATION
NOTE
If ROPS has been replaced, notify Direct Support Maintenance to install protective screen angle brackets
by welding (WP 0133 00).
1.
Attach a suitable lifting device to lift points on roof of ROPS (1) and lift ROPS into position over mounts (8).
2.
Install pad (9) to each leg of ROPS (1).
NOTE
Apply antiseize compound to threads of all capscrews before installation.
3.
Install capscrew (7) and nut (6) to each leg of ROPS (1). Tighten capscrews to 900 lb-ft (1220 Nm).
4.
Install grabhandle (5) on ROPS (1) with two capscrews (2), new lockwashers (3) and flatwashers (4).
5.
Repeat step 4 for other grabhandles (5).
6.
Install protective screen (WP 0134 00).
END OF WORK PACKAGE