TM 5-2410-233-23
TORQUE DIVIDER SCAVENGE PUMP REPLACEMENT - CONTINUED
0097 00
REMOVAL - CONTINUED
NOTE
Use a suitable container to capture any draining oil. Dispose of oil IAW local policy and ordinances. Ensure
all spills are cleaned up.
1.
Remove four capscrews (1), washers (2) and split-type
4
1,2
flange (3).
6,7
2.
Remove oil line (4) from scavenge pump (5).
3.
Remove six capscrews (6) and lockwashers (7) that
hold scavenge pump (5) to flywheel housing. Discard
3
5
386-394
4.
Install two 3/8 in. -16NC forcing screws into scavenge
FORCING SCREWS
pump (5).
5.
Slowly and evenly turn forcing screws until scavenge
pump (5) pulls free from flywheel housing.
5
386-395
0097 00-2
|