TM 5-2410-233-23
TRANSMISSION MAGNETIC STRAINER ASSEMBLY AND TORQUE
DIVIDER SUCTION SCREEN MAINTENANCE - CONTINUED
0085 00
MAGNETIC STRAINER ASSEMBLY INSTALLATION
1.
Place four magnets (7) over tube (6) and place into strainer (5) with "THIS SIDE OUT" notice on screen toward top.
2.
Install magnetic strainer assembly (5) into housing (3).
1
2
NOTE
Lubricate new O-ring with a thin coating of
4
clean oil before installation.
3.
Install new O-ring (8) in housing (3).
4.
Install spring washer (4) on top of magnetic screen (5).
5
5.
Place cover (2) on housing (3) and install four nuts (1).
6.
Check level of oil in transmission and add as needed
7
7.
Operate machine and check for leaks (TM 5-2410-
233-10).
6
8
386-343
0085 00-4
|