WATER TEMPERATURE REGULATOR MAINTENANCE
THIS WORK PACKAGE COVERS
Removal, Test, Installation
INITIAL SETUP
Materials/Parts - Continued
Tools and Special Tools
Gasket (6)
Tool kit, general mechanic's (Item 112, WP 0185
References
Shop equipment, common no. 1 (Item 94, WP 0185
Materials/Parts
Equipment Condition
Coolant drained (WP 0060 00)
Antifreeze (Item 1, WP 0184 00)
1
REMOVAL
2
1
1.
Loosen two clamps (1) and slide hose (2) toward radi-
ator.
2.
Remove three capscrews (3), capscrew (4), elbow
flange (5) and two gaskets (6) from cylinder head.
5
Discard gasket.
3.
Remove water temperature regulator (7) and flow con-
4
3
trol (bypass) valve (8) from cylinder head.
6
8
7
386-127
TEST
Place thermometer in container with water. Heat water to 175F (79C).
1.
2.
Submerse water temperature regulator (7) in heated water.
NOTE
Water temperature regulator should start to open at 175F (79C) and be fully open at 195F (91C)
maximum.
3.
Read temperature on thermometer when water temperature regulator (7) starts to open.
4.
Discard water temperature regulator if not fully open at 195F (91C).