TM 5-2410-233-23
ETHER STARTING AID MAINTENANCE - CONTINUED
0057 00
INSTALLATION - CONTINUED
14.
Install adapter (8) into valve (5).
15.
Position nozzle (10) and install into engine intake manifold. If alignment marks are present on nozzle, make sure they
are aligned with longitudinal axis of intake manifold.
16.
Install adapter (9) to nozzle (10).
17.
Install tube assembly (7) to adapters (8 and 9).
7
9
8
10
5
386-274
18.
Install ether canister. See Service in this work package.
19.
Fill cooling system (WP 0060 00).
20.
Check ether starting aid for leaks. Be alert for odor of leaking ether.
END OF WORK PACKAGE