TM 5-2410-233-23
VIBRATION DAMPER REPLACEMENT - CONTINUED
0027 00
CLEANING
WARNING
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low
toxic material. However, it may be irritating to the eyes and skin. Use protective gloves and
goggles. Use in well-ventilated areas. Keep away from open flames and other sources of igni-
tion.
Particles blown by compressed air are hazardous. DO NOT exceed 15 psi (103 kPa) nozzle
pressure when drying parts with compressed air. Use a maximum of 30 psi (207 kPa) when
cleaning components. DO NOT direct compressed air against human skin. Failure to follow
this warning may cause injury or death. Make sure air stream is directed away from user and
other personnel in the area. To prevent injury, user must wear protective goggles or face
shield.
Clean removed parts with solvent cleaning compound. Dry thoroughly with compressed air.
INSPECTION
NOTE
Refer to WP 0176 00 for general inspection instructions.
1.
Inspect vibration damper and adapter for cracks or other damage. Replace if necessary.
2.
Check two dash marks on perimeter of vibration damper. If marks are not aligned, replace vibration damper.
INSTALLATION
1.
Position adapter (3) to hub (4) and crankshaft pulley (5).
2.
Position vibration damper (2) on adapter (3) and install six capscrews (1). Tighten capscrews to 75 lb-ft (102 Nm).
5
2
4
3
1
386-022
3.
Install crankcase guard (WP 0129 00).
END OF WORK PACKAGE