TM 5-2410-233-23
UNIT MAINTENANCE PREVENTIVE MAINTENANCE CHECKS AND
SERVICES (PMCS) - CONTINUED
0009 00
Table 1. Unit Maintenance Preventive Maintenance Checks and
Services (PMCS) for the D7F Tractor - Continued.
LOCATION
ITEM TO
ITEM
MAN-
CHECK/
NO.
INTERVAL
HOURS
SERVICE
PROCEDURE
f.
Check antifreeze solution for adequate freeze protection (TB
13
750-651).
(Con't)
Inspect starting motor for security of mounting, corrosion and dam-
14
Semiannual
Starting
aged or loose wiring. Tighten mounting capscrews and any loose
Motor
connections.
a.
Inspect alternator for secure mounting.
15
Semiannual
b.
Inspect alternator mounting bracket and attaching hardware for
cracks, bends and secure mounting. Tighten any loose attaching
hardware.
c.
Inspect alternator wiring for frays, bare wires, breaks and loose
terminal connections. Tighten any loose terminal connections.
d.
Use a multimeter to check alternator output voltage. Voltage
should read 27-29 volts (WP 0177 00).
a.
Inspect ROPS for cracks, breaks, bends or wear. Check for loose
16
Semiannual
ROPS
or missing mounting hardware.
b.
Inspect ROPS protective screen for damage or loose or missing
mounting hardware.
a.
Inspect steering and brake linkages for bends, cracks or wear
17
Semiannual
Steering and
that could cause failure.
Brakes
b.
Inspect brake pedals for signs of looseness or wear.
0009 00-6
|