TM 5-2410-233-23
TROUBLESHOOTING PROCEDURES - CONTINUED
0006 00
Table 6. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Test backup alarm circuit
16. Backup Alarm Does Not Sound.
voltage.
a. Place battery disconnect
switch in OFF position.
b. Disconnect brown wire
from backup alarm.
c. Set
to
appropriate voltage range.
d. Connect meter positive
lead to brown wire and
meter negative lead to
chassis ground.
BACKUP
ALARM
BLACK WIRE
BROWN WIRE
TO
TO
GROUND
BACKUP
ALARM SWITCH
386-513
e. Place battery disconnect 1. If voltage is indicated, go to
switch in ON position and
Table 6, Malfunction 16, Test
transmission selector lever
2.
in one of the REVERSE
positions. Observe meter.
2. If voltage is not indicated,
place
battery
disconnect
switch in OFF position and
check for blown fuse. Replace
blown fuse with same rated
fuse.
|