Table 6. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ETHER STARTING AID SYSTEM
BATTERY
24 VOLTS
DISCONNECT SW
CIRCUIT
BREAKER
STARTING
STARTING
AID VALVE
AID SW
5A FUSE
START SW
TEMP
STARTER
SW
386-505
14. Engine Cranks But Will Not Start in Cold 1. Check ether canister. Remove If canister is empty, replace with
ether canister. Shake and a full one (WP 0057 00).
Weather (Fuel System Operating Properly).
listen for liquid splashing
inside canister.
2. Check for a blown starting aid Replace blown fuse with a fuse of
fuse.
the same rating.
3. Check starting aid valve
operation.
a. Place battery disconnect
switch in OFF position.
b. Disconnect temperature
switch lead from starting
aid valve.
|