TM 5-2410-233-23
TROUBLESHOOTING PROCEDURES - CONTINUED
0006 00
Table 6. Electrical System Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
c. Connect multimeter leads
5.
Starting Motor Inoperative - Continued.
as shown in illustration
below
to
measure
continuity.
d. Observe
multimeter 1. If continuity is indicated,
reading.
replace starter relay (WP 0177
2. If continuity is not indicated,
repair circuit(s) in question
386-489
11. Test for voltage to start
switch.
a. Place battery disconnect
switch in OFF position.
b. Disconnect orange lead
from start switch BAT
terminal.
c. Set
multimeter
to
appropriate voltage range.
d. Connect
multimeter
positive lead to orange lead
(harness side) and negative
lead to chassis ground.
0006 00-33
|