TM 5-2410-233-10
OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0012 00
Table 1. Operator Preventive Maintenance Checks and Services (PMCS) for D7F Tractor - Continued.
LOCATION
ITEM TO
ITEM
MAN-
CHECK/
NOT FULLY MISSION
NO.
INTERVAL
HOURS
SERVICE
PROCEDURE
CAPABLE IF:
44
f. Ensure batteries are clean and Battery cables are not secure.
(Con't)
battery cables are secure.
g. Close access cover and secure with
two latches.
ACCESS COVER
FILL PLUGS
WINGNUT
HOLD-DOWN
386-082
CABLES
CLAMP
45
Weekly
0.3 Hours Track Roller
Apply GAA grease (Item 7, WP 0019
Frame Inner
bearings under rear of machine.
GAA
GAA
386-069