TM 5-2410-233-10
OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0012 00
Table 1. Operator Preventive Maintenance Checks and Services (PMCS) for D7F Tractor - Continued.
LOCATION
ITEM TO
ITEM
MAN-
CHECK/
NOT FULLY MISSION
NO.
INTERVAL
HOURS
SERVICE
PROCEDURE
CAPABLE IF:
44
Weekly
0.3 Hours Batteries
WARNING
To avoid injury, eye protection and acid-resistant gloves must be
worn when working around batteries. Do not smoke, use open
flame, make sparks or create other ignition sources around
batteries. If a battery is giving off gases, it can explode and
cause injury to personnel. Remove all jewelry such as rings, ID
tags, watches, and bracelets. If jewelry or a tool contacts a
battery terminal, a direct short will result in instant heating,
damage to equipment, and injury to personnel.
Sulfuric acid contained in batteries can cause serious burns. If
battery corrosion or electrolyte makes contact with skin, eyes or
clothing, take immediate action to stop the corrosive burning
effects. Failure to follow these procedures may result in injury
or death.
NOTE
For complete information on servicing batteries, refer to TM 9-
6140-200-14.
a. Release two latches and open battery One or both batteries are
box access cover on left side of missing.
tractor.
b. Inspect batteries for obvious damage Any electrolyte leakage is
such as a cracked case and evident.
electrolyte leakage.
c. Check battery hold-down for Hold-down is damaged or
looseness and damage. If loose, loose.
tighten wingnuts.
d. Check batteries for broken and Broken
and
corroded
corroded connections or frayed/ connections
or
frayed/
burned/melted cables and clamps.
burned/melted cables and
clamps are evident.
e. Remove fill plugs and check
electrolyte level in cells of both
batteries. Level should be 1/8 in. (3
mm) above tops of plates. Add
distilled water as needed to maintain
correct level.