OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0012 00
Table 1. Operator Preventive Maintenance Checks and Services (PMCS) for D7F Tractor - Continued.
LOCATION
ITEM TO
ITEM
MAN-
CHECK/
NOT FULLY MISSION
NO.
INTERVAL
HOURS
SERVICE
PROCEDURE
CAPABLE IF:
38
After
0.2 Hours Fuel Tank
WARNING
DO NOT perform fuel system checks, inspections or
maintenance while smoking or near fire, flames or sparks. Fuel
may ignite, causing damage to machine and injury or death.
DO NOT smoke or permit any open flame in area of machine
while you are servicing fuel system. Be sure hose nozzle is
grounded against filler tube during refueling to prevent static
electricity. Failure to follow this warning may result in injury to
personnel or equipment damage.
Ensure fire extinguisher is in fuel servicing area.
NOTE
Use a suitable container to capture draining water or sediment.
Dispose of drained fluid IAW local policy and ordinances.
Ensure all spills are cleaned up.
a. Drain water or sediment from fuel
tank as follows:
(1) Place a suitable container under
drain hose at left rear of fuel
tank. Open drain valve and allow
all water or sediment to drain.
(2) Close drain valve.
(3) Dispose of drained water and
sediment IAW local policy and
ordinances.