TM 5-2410-233-10
OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - CONTINUED
0012 00
Table 1. Operator Preventive Maintenance Checks and Services (PMCS) for D7F Tractor - Continued.
LOCATION
ITEM TO
CHECK/
ITEM
MAN-
NOT FULLY MISSION
SERVICE
NO.
INTERVAL
HOURS
PROCEDURE
CAPABLE IF:
NOTE
34
(Con't)
Ensure tractor is parked on level ground with transmission in
neutral (N), transmission safety lock lever in locked position,
brake lock lever engaged and implements lowered to the
ground.
h. Shut down engine (WP 0005 00).
35
After
Turbocharger Visually check for oil leaks at turbo- Any oil leaks or soot are
charger. Check for black soot between evident.
turbocharger and muffler.
36
After
Check for evidence of leaks. Ensure Any exhaust
leaks
are
System
mounting is secure.
evident.
37
After
Engine Air
Check precleaner for damage. Ensure Precleaner is damaged or
Precleaner
precleaner is securely installed and clogged.
housing is free of debris.
0012 00-23
|