screw and raise or lower contact point bracket until
(2) Voltage regulator. The voltage regulator
a gap of 0.048 to 0.052 inch is obtained. Tighten
requires two checks and adjustments as follows:
bracket adjustment screw securely after making
(a) Air gap. W i t h b a t t e r y d i s c o n n e c t e d ,
adjustment. When armature is held down so that
check air gap (fig. 4-28). Insert gage on contact
stop rivet rests on magnet core, point gap should be
point side of air gap next to armature stop rivet. If
a minimum of 0.012 inch.
adjustment is needed, loosen bracket adjustment
|