4-46. Generator
(3) Slowly increase engine speed, while
watching ammeter. If generator charging rate
a. Output Test.
increases proportionally with engine speed to its
( 1 ) Disconnect lead from BAT terminal of
rated output, generator is capable of satisfactory
regulator, and connect ammeter in circuit as shown
p e r f o r m a n c e . Do not force generator to exceed
in figure 4-22.
n o r m a l output rating capacity of 30 amperes
(2) With engine idling, connect a jumper lead
during this test.
from generator F (field) terminal to ground on
(4) If output rises steadily to a value less than
generator. This prevents regulator from controlling
rated output then levels off or falls back, check for
(or interfering with) generator output. A regulator
slipping fan belt. If generator does not pass test
d e f e c t will not now prevent operation of the
satisfactorily, replace generator.
generator.
b. Removal (fig. 4-11).
and lock washers at underside of generator.
Disengage generator from fan belt and remove
(1) Open hood and remove panel from left
side of engine compartment.
generator.
c. Installation.
( 2 ) Disconnect and tag leads at generator
terminals.
(1) Reverse procedure in b above, tightening
generator belt to inch finger-pressure deflection
(3) Remove screw which attaches capacitor to
midway between generator pulley and water pump
generator frame, and remove capacitor with lead
pulley.
attached.
(2)
after all electrical
(4) Remove adjusting arm screw and washer.
connections have been made, by briefly shorting
(5) Remove generator mounting bolts, nuts
|