NOTES
-
CONTINUED:
minutes, check filter housing for leaks.
When AOAP laboratory support is not
available, install new filter element each
250 hours.
9. HYDRAULIC SYSTEM FILTER AND
STRAINER. Each 500 hours remove
strainer, clean and reinstall. Remove filter
element, clean filter shell and install new
filter element. After replacement, operate
hydraulic system for 5 minutes, check for
leaks, check level and bring to "FULL"
mark.
10. FINAL DRIVES. Check level each 100
hours. Change gear lubricant only when
required by maintenance repair action,
contamination by water, or other foreign
material. After refill, operate for 5
minutes, check for leaks and bring oil to
full mark.
11. TRACK ROLLERS, TRACK CARRIER
ROLLERS, AND FRONT IDLERS. These
parts are lubricated for life with OE/HDO
lubricant. After reconditioning, use
special lubricator nozzle for refilling with
OE/HDO.
12. LUBRICANTS. The following is a list
Copy of this Lubrication Order will remain
of lubricants with military symbols and
with the equipment at all times, instruc-
applicable specification numbers.
tions contained herein are mandatory.
By order of the Secretary of the Army:
OE/HDO
MIL-L-2104
GO
MIL-L-2105
JOHN A. WICKHAM, JR.
MIL-G-10924
GAA
General, United States Army
OEA
MIL-L-46167
Chief of Staff
( S D ) , Type II
P-D-680
OFFICIAL:
ROBERT M. JOYCE
Major
General, United States
Army
The Adjutant General
DISTRIBUTION:
To be distributed in accordance with
DA Form 12-25B, Operator and Organi-
zational maintenance requirements for
Full Tracked Tractors.
TA 218825
LO 5-2410-233-12
CARD 7 0F 7
|