NOTES - CONTINUED:
Each 1000 operating hours change transmission oil.
After refill, operate for 5 minutes, check for leaks, stop
engine, check oil level and bring to "FULL" mark.
Disconnect filler tube at transmission to drain and re-
connect to fill transmission. Drain when lubricant is
warm.
15. DIFFERENTIAL. Each 250 operating hours
check level. Change gear lubricant only when required
by maintenance repair action, or contamination by water
or other foreign material. To drain remove capscrew in
lower side of housing cover. After refill operate for 5
minutes, check for leaks and bring to "FULL" mark.
16. LUBRICANTS.
The following is a list of
lubricants with military symbols and applicable
specification numbers.
OE/HDO
MIL-L-2104
GO
MIL-L-2105
GAA
MIL-G-10924
OEA
MIL-L-46167
BFS
MIL-B-46176
(SD), Type II
P-D-680
PL-M
MIL-L-3150
Copy of this Lubrication Order will remain
PL-S
VV-L-800
with the equipment at all times,
instructions contained herein are
mandatory.
By order of the Secretary of the Army:
JOHN A. WICKHAM, JR.
General, United States Army
Chief of Staff
OFFICIAL:
ROBERT M. JOYCE
Major General, United States Army
The Adjutant General
DISTRIBUTION:
To be distributed in accordance with DA Form 12-25A,
Operator and Organizational maintenance requirements
for Wheeled Warehouse Tractors.
LO 10-3930-408-12
U. S. GOVERNMENT PRINTING OFFICE: 1984-420-903/252
CARD 6 OF 6
|