NOTES:
9. DROP GEARCASE. Each 250 operating hours
check level. Change gear lubricant only when required
by maintenance repair action, or contamination by water
1. FOR OPERATION OF EQUIPMENT IN
or other foreign material. Drop gearcase drains through
PROTRACTED COLD TEMPERATURES BELOW -15F
differential drain. After refill, operate for 5 minutes,
(-26C).
Remove lubricants prescribed in Key for
check for leaks and bring oil to "FULL" mark.
temperatures above -15F (-26C). Relubricate with
10. STEERING GEAR. Each 250 operating hours
lubricants specified in Key for temperatures below -15F
check level. Change gear lubricant only when required
(-26C). If OEA lubricant is required to meet the
by maintenance repair action, or contamination by water
temperature ranges prescribed in the Key, OEA lubricant
or other foreign material. Remove capscrew from lower
is to be used in place of OE/HDO-10 lubricant for all
left side of housing end cover to drain. After refill,
temperature ranges where OE/HDO-10 is specified in
operate for 5 minutes, check for leaks and bring oil to
the Key.
"FULL" mark.
2. OIL CAN POINTS. Each 250 operating hours
11. BRAKE MASTER CYLINDER.
Each 250
lubricate control linkages, pins and clevises, and all
operating hours check level and maintain to 1/4-inch (0.6
exposed adjusting threads with OE/HDO.
cm) from top with BFS.
3. ENGINE OIL LEVEL HOT OR COLD CHECK.
Cold engine, oil level should be at high mark on dipstick.
WARNING
hot engine, oil level must be between high and low marks
Particles blown by compressed air
on dipstick (allow to set 5 minutes before checking).
are hazardous. Make certain the air
4. ENGINE CRANKCASE. Oil is to be changed
stream is directed away from user
each 250 operating hours. Drain when oil is warm.
and other personnel in the area. To
5. ENGINE OIL FILTER. Each 250 operating
prevent injury user must wear safety
hours remove filter element, clean housing and install
goggles or face shield when using
new filter element. After installing new filter element, fill
compressed air.
crankcase, operate engine for 5 minutes, check housing
for leaks, check crankcase oil level and bring to "FULL"
12. DRIVE AXLE VENT PLUG. Each 250 operating
mark.
hours remove plug, clean with approved dry cleaning
6. DISTRIBUTOR.
Each 250 operating hours
solvent, blow out with compressed air, and install plug.
lubricate breaker arm pivot and wick under rotor with one
13. AIR CLEANER. Each 250 operating hours
or two drops of PL. Wipe breaker cam lightly with GAA.
disassemble entire unit, clean, assemble and refill with
Remove housing plug and fill reservoir with PL. Avoid
OE/HDO.
excessive lubrication.
14. TRANSMISSION.
Check oil level each 10
7. WHEEL BEARINGS.
Each 1000 operating
operating hours with oil at operating temperature and
hours remove wheels, clean and inspect all parts,
engine stopped. Maintain level to "FULL" mark with
replace worn or damaged parts, repack bearings, and
OE/HDO.
assemble.
8. GENERATOR.
Each 250 operating hours
OE/HDO. Avoid excessive lubrication.
TA 220621
LO 10-3930-408-12
CARD 5 OF 6
|