Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive
electrical circuits a direct short may result. Damage to equipment, injury or death to personnel may
result.
CONTINUITY TEST
(1) Disconnect top harness connector
from OSS box.
(2) Loosen six screws and remove six
clips from crane main junction box
cover.
(3) Remove cover from junction box.
(4) Set multimeter to ohms scale.
(5) Check continuity between harness
connector, terminal B and junction
box, terminal 18.
(a) If no continuity is present,
repair harness (Para 6-29).
(b) If continuity is present, perform
Step (6) below and replace OSS
box (Para 6-8).
(6) Install cover on junction box with
six screws and clips.