TM 9-2320-312-24-2
Troubleshooting Section
Service Tool Display or Lamps The Caterpillar
System Response:
Electronic Technician (ET) will display "NO COMM"
on the status screen next to the inputs that are not
Electronic System Response Communications
receiving communications.
with other control modules that use the J1939 data
link may be interrupted while this diagnostic code
Perform the following diagnostic procedure:
is active.
"Powertrain Data Link Circuit - Test"
Note: If the vehicle is not using the J1939 data link,
program "Powertrain Data Link" to "None". After the
Results:
"Powertrain Data Link" is programmed correctly this
OK STOP.
active diagnostic code should deactivate.
Troubleshooting:
i01641146
0232-03 5 Volt Supply Above
Contact the OEM dealer in order to determine if the
vehicle was configured for the J1939 data link. If the
Normal (21)
vehicle is not using the J1939 data link, program
"Powertrain Data Link" to "None". This will correct
SMCS Code: 1408-081; 1900-038; 1901-038
the problem.
Conditions Which Generate This Code:
If the vehicle is using the J1939 data link, proceed
with the following procedure:
The supply voltage for the pressure sensors of the
engine is exceeding a level that is normal.
Perform the following diagnostic procedure:
"Powertrain Data Link Circuit - Test"
System Response:
Results:
Electronic System Response All pressure sensors
of the engine are set to default values. All diagnostic
OK STOP.
codes for the pressure sensors of the engine are
disabled while this diagnostic code is active.
i01617802
Service Tool Display or Lamps Caterpillar
0231-12 J1939 Device Not
Electronic Technician (ET) will display the default
Responding
status of the sensors. This default status is indicated
in the following list:
SMCS Code: 1901-038
Boost pressure 0 kPa (0 psi)
Conditions Which Generate This Code:
Engine Oil Pressure 600 kPa (87 psi)
This condition indicates that the J1939 data link has
Atmospheric Pressure 100 kPa (15 psi)
a short circuit or an open circuit. All of the following
conditions must be met:
Injection Actuation Pressure 17.5 kPa (2.53 psi)
The parameter "Powertrain Data Link" must be
Injection Actuation Driver Current 40%
programmed J1939.
The ECM is unsuccessful in receiving a response
ET will also display "DIAG" next to the status of
the sensor in order to indicate that the sensor is
to a message that has been transmitted for 10
operating at the value that is shown due to an active
seconds.
diagnostic code.
Electronic System Response J1939
Engine Response An active diagnostic code may
communications to the engine and from the
not cause any noticeable effect on engine response.
engine are terminated while this code is active. The
However, the active diagnostic code may cause the
functionality of some features may be affected while
engine to have the following effects:
this code is active. Traction control or transmission
controls may be disabled.
Run rough.
Low power