Click here to make tpub.com your Home Page

Page Title: DISASSEMBLY - CONTINUED
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home
   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 5-2410-237-23
BLADE LIFT CYLINDER REPAIR - CONTINUED
0221 00
DISASSEMBLY - CONTINUED
7.
Remove seal (10), preformed packing (11) and gasket (12) from head (1). Discard seal, preformed packing and gasket.
8.
Remove O-rings (13 and 14) from inner groove on head (1). Discard O-rings.
9.
Remove two retainer packings (15) and ring spacer (16) from piston (9). Discard retainer packings and ring spacer.
13
14
9
1
15
16
11
387-722
12
387-723
10
CLEANING AND INSPECTION
WARNING
Solvent cleaning compound MIL-PRF-680 Type III is an environmentally compliant and low toxic mate-
rial. However, it may be irritating to the eyes and skin. Use protective gloves and goggles. Use in well-venti-
lated areas. Keep away from open flames and other sources of ignition.
1.
Clean all sealing surfaces and tube assembly connections with solvent cleaning compound and allow to dry.
2.
Inspect internal casing of cylinder and internal parts of cylinder for cracks, wear, scoring and damage. If components
and parts are not serviceable, replace lift cylinder.
3.
Ensure mating surfaces for bearing sleeves are clean and not damaged.
0221 00-3

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business