TM 9-2320-364-34-1
11. FAULT CODE 060, 061, 071 OR 072: TEMPERATURE SENSOR OPEN CIRCUIT,
TEMPERATURE SENSOR SHORT CIRCUIT, OVERHEAT SENSOR OPEN CIRCUIT
OR OVERHEAT SENSOR SHORT CIRCUIT (CONT).
2.
KNOWN INFO
TEST OPTIONS
WARNING
Read WARNING
Arctic heater temperature sensor
Continuity test.
on Page 2-733.59
OK.
POSSIBLE PROBLEMS
REASON FOR QUESTION
Is resistance across arctic
If resistance reading is between
Arctic heater overheat sensor
heater overheat sensor be-
10K and 150K ohms, arctic heat-
faulty.
er control unit may be faulty. If
Arctic heater control unit faulty.
tween 10K ohms and 150K
not, arctic heater overheat sen-
ohms at room temperature?
sor is faulty.
Replace arctic heat-
er overheat sensor
(Para 18-2.2). Verify
NO
repair, go to Step 3
of this Fault.
YES
Replace arctic
heater control unit
(Para 18-2.2).
Verify repair, go to
Step 3 of this
Fault.