TM 9-2320-364-34-1
2-17.1. ARCTIC HEATER (MODEL B) TROUBLESHOOTING (CONT).
11. FAULT CODE 060, 061, 071 OR 072: TEMPERATURE SENSOR OPEN
CIRCUIT, TEMPERATURE SENSOR SHORT CIRCUIT, OVERHEAT
SENSOR OPEN CIRCUIT OR OVERHEAT SENSOR SHORT CIRCUIT.
INITIAL SETUP
References
TM 9-2320-364-10
Tools and Special Tools
TM 9-2320-364-20
Tool Kit, General Mechanic's: Automotive
(Item 241, Appendix F)
Equipment Condition
STE/ICE-R (optional) (Item 15, Appendix F)
Engine OFF, (TM 9-2320-364-10)
Multimeter (Item 140, Appendix F)
Parking brake applied, (TM 9-2320-364-10)
Fault Code Retrieval Device (FCRD)
Wheels chocked, (TM 9-2320-364-10)
(Item 60.1, Appendix F)
NOTE
The following steps should only be used if troubleshooting was started at First Chart
For Diagnosis of Arctic Heater Troubleshooting procedure (Para 2-17.1 Fault 1) (all
conditions) and you were referred here.
START
1.
WARNING
KNOWN INFO
TEST OPTIONS
Read WARNING
Continuity test.
on Page 2-766.73
Nothing.
STE/ICE #91.
POSSIBLE PROBLEMS
REASON FOR QUESTION
Arctic heater temperature
If resistance reading is not be-
sensor faulty.
Is resistance measured across
tween 650 and 1000 ohms at
Arctic heater overheat sensor
arctic heater temperature sen-
room temperature, arctic heater
faulty.
temperature sensor is faulty.
sor between 650 and 1000
Arctic heater control unit faulty.
ohms, at room temperature?
Replace arctic
heater temperature
NO
sensor (Para
18-2.2). Verify re-
pair, go to Step 3
of this Fault.
YES
2-728