TM 9-2320-364-34-1
9. FAULT CODE 051: FAULTY FLAME RECOGNITION (CONT).
2.
KNOWN INFO
TEST OPTIONS
WARNING
Arctic heater flame sensor OK.
Verify repair.
Read WARNING
Arctic heater control unit OK.
on Page 2-733.67
REASON FOR QUESTION
POSSIBLE PROBLEMS
If arctic heater operates normally,
fault has been corrected.
Does arctic heater operate
normally?
If arctic heater indicator
light flashes or fault code
retrieval device (FCRD)
displays fault code 051,
fault not corrected. Notify
supervisor.
NO
If arctic heater indicator
light flashes or fault code
retrieval device (FCRD)
displays fault code other
than 051, troubleshoot fault
code displayed (TM
9-2320-364-20).
YES
Fault corrected.
2-662
83
|