Page Title: FAULT CODE 051: FAULTY FLAME RECOGNITION.
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-364-34-1
2-17.1. ARCTIC HEATER (MODEL B) TROUBLESHOOTING (CONT).
9. FAULT CODE 051: FAULTY FLAME RECOGNITION.
INITIAL SETUP
References
TM 9-2320-364-10
Tools and Special Tools
TM 9-2320-364-20
Tool Kit, General Mechanic's: Automotive
(Item 241, Appendix F)
Equipment Condition
STE/ICE-R (optional) (Item 15, Appendix F)
Engine OFF, (TM 9-2320-364-10)
Multimeter (Item 140, Appendix F)
Parking brake applied, (TM 9-2320-364-10)
Fault Code Retrieval Device (FCRD)
Wheels chocked, (TM 9-2320-364-10)
(Item 60.1, Appendix F)
NOTE
The following steps should only be used if troubleshooting was started at First Chart
For Diagnosis of Arctic Heater Troubleshooting procedure (Para 2-17.1 Fault 1) (all
conditions) and you were referred here.
START
1.
WARNING
KNOWN INFO
TEST OPTIONS
Read WARNING
on Page 2-766.65
Nothing.
STE/ICE #91.
POSSIBLE PROBLEMS
REASON FOR QUESTION
If resistance reading is be-
Arctic heater flame sensor
Is resistance across arctic
tween 900 and 1100 ohms at
faulty.
heater flame sensor between
room temperature, arctic heater
Arctic heater control unit faulty.
control unit may be faulty. If
900 and 1100 ohms, at room
not, arctic heater flame sensor
temperature?
is faulty.
Replace arctic
heater flame sen-
sor (Para 18-22).
NO
Verify repair, go to
Step 2 of this
Fault.
YES
Replace arctic
heater control unit
(Para 18-2.2).
Verify repair, go to
Step 2 of this
Fault.
2-640